Inspection Date:

  

 

 

                                                                                                       

PROPERTY DESCRIPTION:

Orientation

Building Type:

 INTERIOR LAYOUT:  The main dwelling contains:-

AGE:


 

GENERAL SUMMARY:

 

SUMMARY OF OBSERVATIONS & MAJOR DEFECTS:

 

AREAS INSPECTED:

Areas Not Accessible

All areas with less than 400mm crawl space were not accessible.

Areas concealed by stored items, furniture, fixtures & fittings within dwelling. (The dwelling was occupied at the time of inspection).

Areas concealed by  fixtures & fittings within dwelling. (The dwelling was not occupied at the time of inspection).

No access could be gained under front porch concrete slab on fill flooring.

No access could be gained under concrete slab on ground flooring

No access could be gained into the roof void of the skillion roof/s

No access was gained to lower roof void.

No access was gained into the dwelling attached to the inspected dwelling

Areas where Visual Inspection was Obstructed

The dwelling was occupied at the time of the inspection.

The dwelling was not occupied at the time of the inspection.

Thermal insulation over ceiling linings.

Sarking to underside of roof of dwelling.

Stored items located within the garage

Air conditioning ducting located within the roof void of the dwelling.

Plant overgrowth against the exterior of the building/s

CEILINGS

The fabric of the ceilings appears to be gypsum plasterboard.

The ceilings appeared to be in a satisfactory condition.

The cornices have cracks that may need repair prior to decoration. Cracks to cornices are common in this type of construction.

The gypsum plasterboard ceiling linings have not been installed as per Australian Standard, it is common for ceilings of this type not to fully comply with the Australian Standard. Ceilings appear to be satisfactory and no repairs appear necessary.

 

SMOKE DETECTORS:

ALARM:

WALLS:

The fabric of the walls appears to be gypsum plasterboard on timber frame.

Internal wall linings appear to be in a generally satisfactory condition.

The internal walls were checked with a moisture meter at the time of the inspection and found to be generally dry.

The gypsum plasterboard linings often have visible joints under certain lighting conditions, this is commonly known as shadowing. This is common in this type of material.

DOORS:

Timber doors with paint finishes and/or aluminium sliding doors.

Aluminium sliding doors may need new wheels as part of general ongoing maintenance.

Glazed doors appear not to have safety glass installed, the glass could cause bodily injury if broken.

Door panels have indentations and markings that are consistent with the age of the dwelling.

The doors generally appeared to be in adequate working order

 

WINDOWS:

Aluminium windows

Aluminium sliding windows may need new wheels as part of general ongoing maintenance.

No higher than normal moisture readings were recorded around the aluminium windows at the time of the inspection.

No broken panes of glass were observed at the time of the inspection.

Windows appeared to be in satisfactory working order at the time of the inspection.

 

WOODWORK:

The standard of the joinery and condition of the woodwork in paint finish appears to be satisfactory.

Woodwork has markings and indentations consistent with the age of the dwelling.

The timber architraves and skirting boards appear to have been installed in a tradesman's like manner.

 

FLOORS:

Suspended timber flooring and/or suspended concrete flooring and/or concrete slab on ground flooring.

Bathrooms have tiled flooring with visible floor wastes.

Kitchen has tiled flooring.

Other flooring has wall to wall carpets and/or tile floor coverings.

Flooring of the dwelling appears to be generally level, the flooring was not checked with a spirit level and the floors may have slight falls.

Timber flooring that may have been installed very tight without adequate allowance for expansion will often creak during periods of higher humidity.

The flooring appears to be uneven under floor coverings, the cause of the uneven flooring could not be adequately determined without the removal of the floor coverings. Repairs to the uneven flooring may be needed in future.

HEATING/COOLING:

No fixed heating or cooling appliances observed at the time of the inspection

 

STAIR:

Internal closed tread timber stair with carpeted coverings appeared to be in a satisfactory condition.

Stored items located under the closed tread internal timber stairs partially obstructed visual inspection of stair timbers, as the timbers have direct contact with ground flooring it is possible that termites may go undetected.

Stair timbers have direct contact with ground flooring, it is possible that termites may go undetected.

 

KITCHEN:

The kitchen has laminated particle board benchtop, electric stove, non ducted rangehood over stove and tiled flooring.

No significant water hammer was heard in kitchen taps at the time of the inspection.

The interface of the kitchen benchtop and the tiled splashback may need to be sealed to minimise moisture penetrating the rear of the kitchen cupboards.

The shelving under the kitchen sink has visible moisture damage due to higher humidity and leaks, repairs may be needed.

The kitchen cupboard doors may need to be eased and adjusted as part of general ongoing maintenance.

The kitchen cupboards have chipped and marked surfaces.

 

BATH/SHWR/TOILET:

The bathroom flooring has tiled floor covering. There is a visible floor waste.

The bathroom appears to be generally satisfactory

The fixtures appeared to be in a generally satisfactory condition.

The bath and shower recesses and surrounding areas were tested and there were no visible signs of significant water penetration to surrounding areas.

There was no significant water hammer at the time of the inspection.

The tiled wall of the bath has no vents fitted, these are important as condensation will form on the exterior of the bath when filled with hot water. The moist conditions could attract termite activity. It is recommended to have vents installed.

The spa function of the bath was not tested at the time of the inspection. To correctly check the function of the spa the bath would need to be filled with water and the spa operated. It would be prudent to have this item checked, possibly by a plumber or other professional who is qualified to check this item.

Toilet bowl is stable, no cracks in porcelain and no leaking seals detected at the time of inspection.

The vanity unit within the bathroom appeared to be generally satisfactory.

Extraction fan fitted.

 

SHOWER/TOILET: ensuite

The ensuite flooring has tiled floor covering. There is no visible floor waste.

The ensuite appears to be generally satisfactory

The fixtures appeared to be in a generally satisfactory condition.

The shower recess and surrounding areas were tested and there were signs of apparent water penetration to surrounding areas.

There was a water hammer heard at the time of the inspection.

Toilet bowl is unstable and needs to be re-bedded to the tiled flooring by a plumber, no cracks observed in porcelain and no leaking seals detected at the time of the inspection.

Toilet bowl is stable, no cracks in porcelain and no leaking seals detected at the time of inspection.

The vanity unit within the bathroom appeared to be generally satisfactory.

The vanity unit within the bathroom appeared to have moisture damage and may need future repair/replacement.

No extraction fan fitted.

 

SHOWER/TOILET:

The bathroom flooring has tiled floor covering. There is a visible floor waste.

The bathroom appears to be generally satisfactory

The fixtures appeared to be in a generally satisfactory condition.

The shower recess and surrounding areas were tested and there were no visible signs of significant water penetration to surrounding areas.

There was no significant water hammer at the time of the inspection.

Toilet bowl is unstable and needs to be re-bedded to the tiled flooring by a plumber, no cracks observed in porcelain and no leaking seals detected at the time of the inspection.

Toilet bowl is stable, no cracks in porcelain and no leaking seals detected at the time of inspection.

The vanity unit within the bathroom appeared to be generally satisfactory.

The vanity unit within the bathroom appeared to have moisture damage and may need future repair/replacement.

Extraction fan fitted.

 

BATH/SHOWER:

The bathroom flooring has tiled floor covering. There is a visible floor waste.

The bathroom appears to be generally satisfactory

The fixtures appeared to be in a generally satisfactory condition.

The bath and shower recesses and surrounding areas were tested and there were no visible signs of significant water penetration to surrounding areas.

There was no significant water hammer at the time of the inspection.

The tiled wall of the bath has no vents fitted, these are important as condensation will form on the exterior of the bath when filled with hot water. The moist conditions could attract termite activity. It is recommended to have vents installed.

The vanity unit within the bathroom appeared to be generally satisfactory.

Extraction fan fitted.

 

BATH/TOILET:

The bathroom flooring has tiled floor covering. There is a visible floor waste.

The bathroom appears to be generally satisfactory

The fixtures appeared to be in a generally satisfactory condition.

The bath recess and surrounding areas were tested and there were no visible signs of significant water penetration to surrounding areas.

There was no significant water hammer at the time of the inspection.

The tiled wall of the bath has no vents fitted, these are important as condensation will form on the exterior of the bath when filled with hot water. The moist conditions could attract termite activity. It is recommended to have vents installed.

Toilet bowl is unstable and needs to be re-bedded to the tiled flooring by a plumber, no cracks observed in porcelain and no leaking seals detected at the time of the inspection.

Toilet bowl is stable, no cracks in porcelain and no leaking seals detected at the time of inspection.

The vanity unit within the bathroom appeared to be generally satisfactory.

The vanity unit within the bathroom appeared to have moisture damage and may need future repair/replacement.

Extraction fan fitted.

 

TOILET:

The toilet has tiled floor covering. There is a visible floor waste (drain).

The toilet appears to be generally satisfactory

The toilet bowl is stable, no cracks observed in porcelain and no leaking seals detected at the time of the inspection.

No extraction fan fitted.

 

TOILET:

The toilet has tiled floor covering. There is a visible floor waste (drain). The fixtures appeared to be in a generally satisfactory condition.

The toilet appears to be generally fair 

The toilet bowl is stable, no cracks observed in porcelain and no leaking seals detected at the time of the inspection.

No extraction fan fitted.

 

LAUNDRY:

The laundry has tiled flooring with no visible floor waste. The laundry fixtures appeared to be in a generally satisfactory condition.

Laundry fixtures appeared to be in working order.

No extraction fan has been installed, the use of a clothes drier creates humidity, it is important to extract this humidity when using the close drier, excessive moisture will reduce the material durability of fixtures and linings within the laundry.

 

SERVICES:

The water lines where visible are of copper pipe and water pressure appeared normal in all taps.

No significant water hammer was heard at the time of the inspection.

The water flow appeared to be satisfactory.

Water hammer may increase at night when the water pressure in the pipes increases.

If water hammer occurs a plumber can fit a pressure equaliser valve on the water line to minimise water hammer.

 

            The water lines where visible are copper pipe and water pressure was normal at the time of the inspection. It would be prudent to have all services including electrical wiring, plumbing lines, smoke testing of sewerage, smoke testing of stormwater etc' checked by appropriately qualified contractors.

 

            It is not possible for the inspector at the time of the inspection to test the expected performance of stormwater drains or roof drainage, gutter systems, capping and/or roof leaks during normal or heavy rain conditions. The inspector is unable to assess and/or examine the condition of stormwater drainage for blockages and/or obstructions and/or breaks and/or faulty joints. Therefore no comment can be made on their condition and/or performance.

            Trees near guttering can deposit leaves in guttering and drains, cause blockages, accelerated deterioration of materials and tree roots often damage in-ground services.

 

            Water hammer refers to the banging noises often associated with a plumbing system. It is caused by sudden changes of water pressure in the pipes, especially in longer runs of loose pipe. Water hammer has numerous causes, although in simplified terms, water that flows through a tap and pipes is abruptly shut off the inertia of the water tries to compress the water in the tap, which then pushes back causing a shock wave. The same can happen in reverse when the tap is suddenly opened.

            In the majority of cases this shock wave is absorbed by the plumbing system. In some cases where the shut off is severe and pipes are loose a loud banging of the pipes can be heard. The sounds are amplified if the loose pipes vibrate and/or bang against the frame of the building and/or other pipes.

            The main problem occurs in the fixtures that use large amounts of water and the water passes through large openings and/or solenoid valves where pressure variation is greater. These areas often include the washing machine and dishwasher.

            The initial remedy where access is available is to secure all pipes with saddles to the building frame. This will minimise the transfer of sound into the building frame. You may also need to install a pressure equaliser valves (water hammer arrestor) in the plumbing line.

            A pressure equaliser valve is a shock absorber that absorbs the shock wave created by sudden shut off, prior to the shock wave having a chance to back up the system. Pressure equaliser valves need to be installed by a plumber, as close as possible to the offending fixture and/or elbow and/or T-junction to minimise the shock passing through long lengths of pipe.

 

HOT WATER SERVICE:

The hot water unit is an electric unit with mains pressure. The unit has a 315 litre storage capacity, located along the southern side of dwelling, externally. The units date of manufacture is undetermined.

No indication can be given as to the life expectancy of the hot water unit as failure is likely to occur at any time.

As a guide, mains pressure hot water units have an expected life of 8 to 12 years. Hot water units nearing, or older than, this age are generally considered to be nearing the end of unit durability.

 

GAS:

DUCTED VACUUM SYSTEM:

ANTENNA:

 

ELECTRICAL:

ATTIC/ROOF TIMBERS:

Trussed timber framed roof.

Conventional timber framed roof.

Thermal insulation over ceiling linings, the thermal insulation obstructed visual inspection of the ceiling joists and wall top plates.

No thermal insulation over ceiling linings

Sarking to the underside of roof tiles, the sarking conceals the roof tile battens and the underside of roof tiles.

No sarking to underside of roof tiles.

Stored items located within the roof void at the time of the inspection.

Air conditioning ducting located within the roof void partially obstructed visual inspection of the roofing timbers at the time of the inspection.

Obsolete hot water unit is located within the roof void, the unit appears to have been disconnected and drained of fluids.

No access could be gained into the roof void of the skillion roof.

No access could be gained into the lower level roof void.

Roof trusses were observed visually and appeared to have been levelled, the trusses were not checked with a spirit level and therefore the trusses may have slight lean.

Lead flashing to base of dutch gable end is torn and may need future repair.

The gable ends had evidence of moisture penetration when viewed from within the roof void.

 

            This building report does not include any identification or detection of any pests, pest related issues should be detailed in a pest report.

 

ROOF:

The inspected building has a concrete tiled hip & valley roof.

The valley metals appear to be satisfactory.

The valley metals appear to have rusted surfaces and future replacement of valley metals may be considered.

The ridge and hip tile mortar appeared generally satisfactory, localised pointing of mortar may be needed as part of general ongoing maintenance.

Skillion roofing attached to the rear of the dwelling, the skillion roofing appeared to be satisfactory.

The roof was observed from a 3.6 meter ladder along the edges of the roof where possible, it is not common practice to climb onto the roof for inspection as damage may occur.

Slight deflections observed in the roof line, the deflections were checked and appear to be of a non structural nature.

The interface of the skillion roofing and the tiled roofing does not appear to be an ideal detail, no leaks to surrounding areas were observed at the time of the inspection.

No rotary extraction fan has been fitted to the roof line, it would be prudent to have a rotary extraction fan (whirlybird) fitted to the roof line.

The roof may need to be upgraded in the foreseeable future.

No comment has been made on the condition of penetration flashings as leaks to this type of flashing often occur during periods of rain as sealants are exposed to extreme variations in weather conditions, future repairs to penetration/s may be needed as part of general ongoing maintenance.

 

GUTTERS/DOWNPIPES:

Internal condition of the guttering appeared to be reasonable. The internal condition of the downpipes appeared adequate.

Downpipes appear to be connected to the dispersal system.

No significant leaks were detected at the time of the inspection.

The guttering contains leaf litter and silt, silt will retain moisture for extended periods of time therefore increasing the deterioration of the guttering material significantly.

It is recommended to have the guttering cleaned on a regular basis as part of general ongoing maintenance.

The downpipes have holes created close to ground level, this often indicates that the stormwater dispersal system is blocked. Further inspection of the dispersal system by a plumber may be needed.

EAVES/FASCIAS:

The eaves soffit linings appear to be fibro.

The timber fascias appeared to be satisfactory at the time of the inspection.

 

EXTERNAL WALLS:

The external walls are face brick, no significant structural faults were observed.

The external brickwork has visible cracks, these cracks would need to be monitored over time by an appropriate professional, ideally any cracks should be assessed by a structural engineer.

Timber posts attached to the external walls have direct contact with the ground and termites could go undetected, it is recommended to alter this detail.

The soil levels along the side of the dwelling need to be lowered as termites could go undetected.

The weep holes and dampcourse are partially concealed by raised soil levels and termites could go undetected.

Plant overgrowth against the external walls could provide pests with concealed entry points, it is recommended to remove plant growth away for external walls of the dwelling to deter possible termite damage.

The concrete slab edge is not adequately exposed and soil levels should be lowered, the slab edge should have 50mm - 100mm exposed around the entire building where possible, an exposed slab edge enables visual detection of termite mud trails during periodic visual termite inspections.

The finished level of paths attached to external walls of the dwelling have finished level above dampcourse and termites could go undetected.

 

 WINDOWS EXTERIOR:

The external condition of windows was generally satisfactory.

 

DAMP:

Internal walls were checked with moisture meter at the time of the inspection.

No significant damp was detected at the time of the inspection in the internal walls.

 

DAMPCOURSE:

Dampcourse where sighted at the time of the inspection appeared to be effective.

 

SUB-FLOOR:

The ground of the sub-floor areas appeared to be generally dry at the time of the inspection.

The ventilation of the sub-floor areas appears to be in-adequate. Improvements to the cross flow ventilation of the sub-floor should be considered.

The sub floor is accessible from the rear side of the dwelling.

 

FOUNDATIONS:

Brick pier and/or brick engaged pier and/or brick dwarf wall foundations.

Foundations generally appeared to be load bearing.

Foundations appear to have settled over time and wedges may need to be inserted between floor bearers and foundations for ongoing support of live loads.

No significant cracks were observed to dwarf wall foundations of dwelling.

Cracks were observed to the foundations of the dwelling, all cracks are a concern and should ideally be assessed by a structural engineer then monitored by an appropriate building professional over time for possible future movement.

It is recommended to cut additional openings in dwarf wall foundations to increase cross flow ventilation within the sub-floor.

Concrete slab on ground flooring has undetermined foundations.

 

 

PATHWAYS/DRIVEWAY:

The crossover of council nature strip to street is a sealed surface.

The driveway appeared to be generally adequate.

Paths and paved surfaces appeared to be generally even.

The site drainage appears to be generally adequate.

 

FENCES:

Timber paling fences and/or metal colorbond fences.

Timber paling fences were partially concealed by plant overgrowth.

Timber paling fences were found to be weathered. This is consistent with the age of the materials.

Localised repairs to fences is needed to prolong material durability.

Fences appeared to be generally stable.

 

RETAINING WALLS:

The timber and/or sandstone and/or masonry and/or brick retaining walls appeared to be stable with no evidence of significant slippage and/or movement at the time of the inspection.

Timber garden sleepers and/or timber retaining walls have direct contact with the ground and could conceal termite activity and/or damage. It is recommended to consider replacing these timbers with masonry products to deter termite activity.

Timber retaining walls have evidence of decay, timber retaining walls often attract and/or conceal termite activity. Timbers in direct contact with ground appear to have a reaction with soils that will naturally attract termites as part of the natural decay process.

Treated timbers may generally have a greater durability than natural timbers but are still susceptible to termite damage and decay.

 

CARPORT:

Metal carport attached to the side of the dwelling, the carport appeared to be satisfactory for the intended purpose.

 

GARAGE:

Garage has brick and/or lined walls, lined soffit and motorised roller doors. The garage has internal access door from within dwelling.

The concrete flooring of the garage has cracked surfaces.

The garage contained stored items and furniture at the time of the inspection.

Concrete slab on ground flooring is sometimes placed in (two or more) separate pours of concrete, therefore creating a cold joint or a control joint in the concrete, it is common for termites to gain concealed entry through a cold joint or expansion joint or control joint, cold joints are commonly located under the common wall of garage and the habitable area of the dwelling.

 

FRONT PORCH:

Concrete flooring of the front porch has tiled surfaces.

The front porch area appeared to be in a satisfactory condition.

 

PERGOLA:

Timber pergola with roofing attached to the rear of the inspected dwelling.

External timbers of the pergola are weathered, it is important to properly seal and/or paint these timbers to minimise decay and maximise material durability.

Timber posts of the pergola have direct contact with the ground and termites could go undetected, timbers in contact with the ground will also decay rapidly, it is recommended to sperate these timbers from the ground, this can be achieved by either lowering soil levels and/or installing metal staunches to base of timber posts.

Exposed timbers will often develop decay on the top side of the timbers, this decay may be concealed and may only become evident when decay is advanced.

Note: Pergola does not necessarily comply with the appropriate Australian Standard.

 

TIMBER DECKING:

Timber decking attached to the rear of the dwelling.

External timbers of the decking are weathered, it is important to seal and paint these timbers to prolong material durability and minimise future decay.

The decking handrail has localised decay, future repairs may be needed.

The decking timbers have ground contact and termites could go undetected.

No access was gained under the timber decking, decay and pest damage could go undetected.

 

EXTERNAL STAIRS:

Open tread external timber stairs.

The open tread stairs have timber in direct contact with the ground, termites could go undetected, it would be prudent to consider separation of timbers from the ground to deter possible termite damage and moisture wicking into timber.

External timber stairs have weathered sections.

Closed tread external stair appears to be generally satisfactory

 

BALCONY:

Tiled concrete balcony attached to the front of the dwelling.

Drainage of the balcony appears to be satisfactory.

The interface of the balcony and the external wall had no obvious signs of moisture penetration to surrounding areas.

The handrail of the balcony appears to be satisfactory.

The balcony has slight cracks, no immediate repairs appear necessary.

 

GARDEN SHED/S:

Self standing metal garden shed located in the rear yard appears to be adequate for the intended purpose.

The door of the garden shed may need future repair.

The garden shed contained stored items at the time of the inspection.

The garden shed has inadequate flooring and may need future improvements.

 

CABANA:

Self standing timber framed cabana located in the yard.

Timbers of the cabana are weathered, it is recommended to seal and/or paint these timbers to minimise decay and maximise material durability.

The timber posts of the cabana have direct ground contact and termites could go undetected, it is recommended to separate timbers from the ground by installing metal staunches to the base of the timber posts.

Exposed timbers often develop concealed decay on the top side of the timbers, this decay may only become evident when the decay is advanced.

 

GAZEBO:

Self standing timber gazebo located in the yard.

Timbers of the gazebo are weathered, it is recommended to seal and/or paint these timbers to minimise decay and maximise material durability.

The gazebo posts of the pergola have direct ground contact and termites could go undetected, it is recommended to separate timbers from the ground by installing metal staunches to the base of the timber posts.

Exposed timbers often develop concealed decay on the top side of the timbers, this decay may only become evident when the decay is advanced.

 

GRANNY FLAT:

Self standing timber framed granny flat located in yard with metal skillion roof, concrete slab on ground flooring fibro clad walls and access door from yard.

The timber frame of the granny flat has direct contact with the ground and termites could go undetected.

The external walls of the granny flat have direct contact with the ground and termites could go undetected.

No access could be gained along the southern side of the granny flat, termite damage may go undetected.

The internal flooring of the granny flat has tiles and/or carpeted floor coverings.

No bodily access could be gained into the roof void of the granny flat.

The granny flat contained furniture and stored items the time of the inspection.

The kitchen of the granny flat appeared to be generally satisfactory.

The granny flat bathroom appeared to be satisfactory. The walls surrounding the shower recess had no signs of significant moisture penetration to the surrounding areas.

The granny flat toilet has ceramic tiled floor covering. There is a visible floor waste (drain). The fixtures appeared to be in a generally satisfactory condition.

The granny flat toilet bowl is stable, no cracks observed in porcelain and no leaking seals detected at the time of the inspection.

No exhaust fan fitted.

 

WORKSHOP:

Workshop located under the dwelling.

The timber bench and shelving in the workshop appeared to be satisfactory.

The workshop has exposed concrete flooring with slight cracks.

Timber furniture within the workshop has direct contact with ground flooring and therefore termites could go undetected, it is recommended to consider altering this detail.

 

CONCLUSION:

***

***

 

 

DISCLAIMER OF LIABILITY:

DISCLAIMER OF LIABILITY TO THIRD PARTIES:


 

60     REPORT PICTURE PAGES:

 

IMPORTANT NOTE:

            The following pictures are illustrations of some of the items mentioned in the report, these photos are an aid to understanding the written report and are not intended to define the extent and/or location of reported damage and/or infestations and/or defects that may be shown.

 


 

NON DESTRUCTIVE STRUCTURAL PEST INSPECTION REPORT

 

 

 

Property Description

Self Standing Building

Areas Not Accessible

All areas with less than 400mm crawl space were not accessible.

Areas concealed by stored items, furniture, fixtures & fittings within dwelling. (The dwelling was occupied at the time of inspection).

Areas concealed by  fixtures & fittings within dwelling. (The dwelling was not occupied at the time of inspection).

No access could be gained under front porch concrete slab on fill flooring.

No access could be gained under concrete slab on ground flooring

No access could be gained into the roof void of the skillion roof/s

No access was gained to lower roof void.

No access was gained into the dwelling attached to the inspected dwelling

Areas where Visual Inspection was Obstructed

The dwelling was occupied at the time of the inspection.

The dwelling was not occupied at the time of the inspection.

Thermal insulation over ceiling linings.

Sarking to underside of roof of dwelling.

Stored items located within the garage

Air conditioning ducting located within the roof void of the dwelling.

Plant overgrowth against the exterior of the building/s

 Visual Evidence Of Dormant/Inactive Subterranean Termites:

Termite Damage – Not Observed. Concealed Termite Damage is Suspected.

No visible evidence of significant dormant/Inactive termite activity was sighted at the time of the inspection, due to our observation of conditions conducive to termite activity and/or concealed termite entry at the time of our inspection, a real possibility exists that termite damage does exist as documented research carried out in 1982-83 shows that at least 1 in 5 New South Wales properties have a history of termite damage (Hadlington & Gerozisis), if aged termite damage is inactive and dry then current termite detection technology is generally unable to detect this dormant/inactive termite damage.

Termite Damage – Observed. Concealed Termite Damage is Suspected.

Visible evidence of significant dormant/Inactive termite activity was sighted at the time of the inspection, due to our observation of conditions conducive to termite activity and/or concealed termite entry at the time of our inspection, a real possibility exists that termite damage does exist as documented research carried out in 1982-83 shows that at least 1 in 5 New South Wales properties have a history of termite damage (Hadlington & Gerozisis), if aged termite damage is inactive and dry then current termite detection technology is generally unable to detect this dormant/inactive termite damage.

This report does not itemise all areas of termite damage observed rather has identified the presence of termite damage to property, this would need to be determined by a special purpose report. This report does not presume severity of termite damage observed.

Visual Evidence Of Current Termite Activity:

Current Termite Activity:- Not Observed

Current Termite Activity:- Observed

Coptotermes spp. Schedorhinotermes spp.

No visual evidence of termite activity was found at time of the inspection.

 

During changing weather conditions termite activity will often retreat out of termite workings that are located at a distance from the termites nest to warm the nest and nursery surrounding the termite queen as the termites nest needs a constant temperature at all times for reproduction.

 

Risk Of Future Termite Activity:

The building o considered to have a low to moderate risk of future termite activity at some time in the future.

The building is considered to have a moderate risk of termite activity at some time in the future.

The building is considered to have a moderate to high risk of termite activity at some time in the future

The building is considered to have a high risk of termite activity at some time in the future.

The building is considered to have a higher than normal risk of termite activity at some time in the future

The building is considered to have a significantly higher than normal risk of termite activity at some time in the future.

Previous Termite Protection:

No evidence of previous termite treatment in accordance to AS 3660.1 and/or 3660.2-2000 was observed at time of inspection.

Evidence of previous termite treatment in accordance to AS 3660.1 and/or 3660.2-2000 was observed at time of inspection.

Evidence of previous termite treatment was observed but this treatment does no appear to have been carried out  in accordance to AS 3660.1 and/or 3660.2-2000, a termite preventative treatment is recommended.

 

 Areas Conducive To Termites & Other Observations:

Termites – Conducive conditions were not observed.

Termites – Conducive conditions observed.

 

All areas not accessible and/or obstructed for inspection are to be considered as conducive.

New Timbers:

New or repaired timberwork

Some timbers appear to be new or not the original timbers. This replacement may have been due to timber pest attack or some other factor. We recommend if you are using this report to purchase this property, further enquiries should be made to determine the reason for timber replacement.

Some timbers appear to be new or not the original timbers. This replacement may have been due to timber pest attack or some other factor. Affected subfloor timbers

Termite Treatment Recommendation:

Termite treatment - Not Currently Recommended.      A preventative/barrier termite treatment in accordance with Australian Standards 3660.2-2000 to control and/or deter Subterranean Termites from infesting and causing damage to the property is Not Currently Recommended.

Termite treatment - Recommended.      A preventative/barrier termite treatment in accordance with Australian Standards 3660.2-2000 to control and/or deter Subterranean Termites from infesting and causing damage to the property is recommended.

****

 

Future Periodic Structural Pest Inspections Recommendation:

Periodic Pest Inspection Recommendation – It is strongly recommended that a structural pest inspection and report should be carried out at least once every Three months based on observations made at time of inspection.

Periodic Pest Inspection Recommendation – It is strongly recommended that a structural pest inspection and report should be carried out at least once every Four months based on observations made at time of inspection.

Periodic Pest Inspection Recommendation – It is strongly recommended that a structural pest inspection and report should be carried out at least once every Six months based on observations made at time of inspection.

Periodic Pest Inspection Recommendation – It is strongly recommended that a structural pest inspection and report should be carried out at least once every Twelve months based on observations made at time of inspection.

 

Invasive Inspection:

A More Invasive Physical Inspection Is Available And Recommended

A More Invasive Physical Inspection Is Available, Further Invasive Inspection in not currently recommended based on observations made at the time of the inspection.

Visible drain leaks:

No significant leaks to sewer pipes and/or stormwater pipes and/or water pipes was observed at the time of the inspection.

Leaks to sewer pipes and/or stormwater pipes and/or water pipes was observed at the time of the inspection, moisture could attract termites and/or cause other damage.

 

BORERS

Visual evidence Of Borer Activity:- Not Observed

Visual evidence Of Borer Activity:- Observed

No significant Lyctus brunneus (Powderpost beetle) evidence was located at time of inspection.

Lyctus brunneus (Powderpost beetle) evidence was located at time of inspection.

No significant Anobium punctatum (furniture beetle) evidence was located at the time of the inspection in the dwelling.

 Anobium punctatum (furniture beetle) evidence was located at the time of the inspection in the dwelling.

Evidence Of Damage Caused By Wood Decay (Rot) By Fungi:

Wood Decay Fungi - Localised

Wood Decay Fungi - Not Observed

 Timber fences are aged with localised decay.

External timbers have initialising decay at joints, it is important to properly seal the timbers to minimise further decay and maximise material durability.

External timbers are weathered, it is important to seal these timbers to maximise material durability.

No significant wood decay was located at the time of inspection.

All external timbers have normal weathering.

 


 

Chemical Delignification:

Chemical Delignification – Not Observed

Chemical Delignification – Observed

The chemical delignification was observed within the roof void of the inspected dwelling at the time of the inspection.

Mortar Bees:

Mortar Bee Damage – Not Observed

Mortar Bee Damage – Observed

 Ant Capping:

Ant Capping – Generally Satisfactory

Ant Capping – Partially Unsatisfactory

Ant Capping – Unsatisfactory

No ant capping has been installed as this was not a common building practice at the time the building was constructed.

The joints in the ant capping have not been fully soldered and termites could go undetected.

Ant capping has evidence of corrosion, therefore the ant capping is considered in-adequate as ant capping can not serve the intended purpose.

Sub-Floor Ventilation:

Sub-Floor Ventilation – Generally Adequate

Sub-Floor Ventilation – Partially Inadequate

Sub-Floor Ventilation – Inadequate

Ventilation to the sub-floor areas appeared to be in-adequate. Additional openings need to be cut in sub-floor dwarf walls to improve the cross flow ventilation.

 

 

                                                                                                   

 

 

 

                                                                                                                                                             

Stephen Koelewyn - NSW Builders Licence 45109c   -   Building Consultant Licence BC213 (Now Obsolete)  -   Pest Control Licence 2025
Home        
Send mail to steve@ausinspect.com.au with questions or comments about this web site.
Links to my site are permitted and would be appreciated.
Copyright © 1992-2012 AUSINSPECT
Last modified: Thursday, 02 February 2012

AUSINSPECT is well equipped to carry out specialised building works, termite treatments, termite nest location, termite nest eradication, effective repairs to buildings and property maintenance. We own our own machinery and truck for efficient, cost effective undertaking of works, our specialty is the repair of termite damaged and decayed structures.

   

Home                Please visit my other web sites,  Handy Pest Control    SkippyBAG  and  4control   and VideoReport

                              My Daughters Recruitment Web Site - SLK Recruitment